6-Ton Earthlinked Direct Exchange System
Existing System Included:
- 90% Carrier Gas Furnace located in Garage combined with 5-Ton Air Conditioner
- 80% Carrier Gas Furnace located in Attic combined with 2-Ton Air Conditioner
- (2) 40,000 Btu Gas Water Heate
r - (2) Honeywell EAC's
New Earthlinked Dx System Includes:
- Complete Home Energy Evaluation (Heating and Cooling Load Calculation)
- Proper Removal of Existing System
- Carrier 3-Stage 90% Infinity Variable Speed Gas Furnace (back-up heat)
- Honeywell Prestige HD Zoning System
- Installation of 6 -Ton Earthlinked Dx Unit equipped with Domestic Hot Water Heating Module
- Drilling & Super Grouting of (6) 100' Vertical Bore holes for Ground Loop installation
- Repair of Landscaping after completion of Drilling and Trenching for Dx Ground Loop
- New 65,000 Btu Gas Water Heater (Back-up)
- New Hot Water Storage Tank for Earthlinked Domestic Hot Water Module
- All Ductwork modification for Zoning